INTERFLUX
00-322 Warszawa
ul. Krakowskie Przedmie¶cie 66
tel. (48 22) 828 48 68
fax. (48 22) 826 59 88
mobile. 0-601 26 90 27
NIP 123-000-47-98
interflux.electronics@bigvent.com.pl
INTERFLUX logistic dep.
87-100 Toruń
ul. Kociewska 28/30
tel. 0-601 89 11 30

interflux | lampy UV | idealtape | cimatec | mec | shipley | emi

w górę

MecEtchBond CZ-8100

DESCRIPTION

MECetchBOND CZ-8100 is a single stage copper surface treatment process which is capable to entirely replace the Black Oxide process for innerlayers.
Many of the typical imperfections of the Black Oxide process can be resolved easily by MecEtchBond CZ-8100.
MecEtchBond is the very latest technology invented, formulated and patented by Mec Company Ltd.

The highly efficient electronic appliances are nowadays in great demand besides the compact and light-weight electronic appliances. Thus, various PWB processes are introduced in order to respond to such demands.

Our newly-developed MECetchBOND CZ-8100 now introduced to you can provide a unique copper surface topography which is not possible to get with any conventional chemical cleaning. This enhances the adhesion between the copper and the resin.

Unlike other technics, MECetchBOND CZ-8100 can easily be employed without requiring the complicated control.

Our newly-developed MECetchBOND CZ-8100 will contribute much to your solution of various problems as well as the improvement of the productivity with the simplification of the process.
 

FEATURES

  1. No pinkring (haloing).

  2. Produces no copper oxide on copper surface.
    Produces roughened copper surface excellent for adhesion to resin.
     
  3. High work efficiency.

  4. Easy to conveyorise, unlike Black Oxide treatment, which will provide high productivity.
     
  5. Simple control.

  6. Can basically be controlled by copper concentration only.
     
  7. Easy waste treatment.

  8. Separation of copper by general neutralisation coagulation method.
     
  9. Improved working environment.

  10. High working temperature is not required as in Black Oxide treatment, which will result in energy saving.
     
  11. Reduced process steps I

  12. This will not only reduce in equipment investment, but also in cc #7,
     
  13. Reduced process steps less rinse water consumption and so also less in water treatment cost.

  14.  
  15. Strong adhesion of copper and resin.

  16. Possible to improve adhesion of copper and resin in build-up structure of ML. ML developed in Japan by IBM.
     
  17. Capable of roughening hard-to-etch materials such as rolled copper and copper alloy.

  18. Can be applied to flexible PCB and lead frame.
     
  19. High copper holding capacity.
 
RECOMMENDED PROCESS & TREATMENT CONDITIONS FOR MecEtchBond

 
MICRO-ETCH 
CZ-8100 make-up 
Refer to USAGE & CONTROL 
for replenishment
 
30 - 40°C (standard 35°C) 
Spray pressure : 1 - 2 kg/cm? 
Etch rate : approx. 1.5 (to 4) µm 
(treatment time : 45-90 sec.)  
 
 
WATER RINSE
 
 
 
 
ACID RINSE
PC-8200 (2 time dilution)
or 10.0% hydrochloric acid
 
20 - 30°C 
Spray pressure : 0.3-0.6 kg/cm? 
Treat for 10-15 sec.
 
 
WATER RINSE
(over 2 steps)
 
 
 
DRY
 
For details, refer to the drawing of our standard machine.
 

PHYSICAL PROPERTIES
 
Item
 MecEtchBond
CZ-8100M
 MecEtchBond
CZ-8100R
 Appearance
Blue clear liquid
Colorless-light
Yellow clear liquid
 Specific gravity
(At 20°C)
1.13 ± 0.01
 1.11 ± 0.01
pH
3.4 ± 0.5
3.1 ± 0.5
 
R : replenisher solution
M : starter
 
 

USAGE AND CONTROL

HOW TO USE

  1. Use CZ-8100 for bath make-up.

  2. - For replenishment, refer to ‘control method’ mentioned below.
  3. Process in spray at temperature : 30-40°C (standard 35°C).

  4. - Oxygen is required in the reaction.
  5. Use a ‘de-smuth’ rinse with 10% of hydrochloric acid.
CONTROL

Control of copper concentration

a) Analytical :

    Read copper concentration according to ‘Analytical Method’.
     
  1. When the copper concentration is below 15g/liter, add fresh CZ-8100 to fill up the solution level.
  2. When the copper concentration is 15-45g/liter, add fresh CZ-8100 to fill up the solution level.
  3. When the copper concentration is over 45g/liter, take out 5/8 of the used solution and add fresh CZ-8100
b) Feed and Bleed :
    Automatic copper control
    The Walchem W-10 series copper controllers are available from Mec Europe.
     
Control of concentration

c) By density control :

Read from the copper concentration mentioned above and SG mentioned in the following page. (be careful of the temperature when measuring).
  1. Measure SG of CZ-8100 solution at 30 ± 1°C (A).
  2. Read SG which corresponds to the analytical measured coper concentration from the graphic (B).
    1.  
     
    B - A
    Concentration x (%) = 
     x 100
    B(1 - A)
     
(Plus value is concentration. Minus value indicates low concentration)   Replenishment

When concentration (X) is :

 
- 10%    change whole solution
- 10% ~ + 10%    Use as it is
+ 10% ~ + 20%    add D.I. water in accordance with formula below
+ 20%    change whole solution
 
 
tank volume (kg) x 100
D.I. water (1) = 
 - tank volume (kg)
100 - concentration (%)
 
Control of de-smuth

Measure the acidity by titration
cc. analytical procedures :

Maintain the bath as follows :
Acid : below 1.0N - change all into fresh solution
 

Control of concentration and dilution.

Read from the copper concentration mentioned above and SG mentioned in the following page; (Be careful of the temperature when measuring.)

Dilution > 1O% : change all into fresh solution.
Concentration & Dilution < 1O% : use as it is.
Concentration 1O-2O% : correct by adding deionized water.
Concentration over 2O% : change all into fresh solution.

In case that the solution may be diluted or concentrated, check the process line.

Dilution : Rinse water drag in or damage of cooling pipe, ect.
Concentration : Too much extraction of exhaust duct of bad control of temperature, etc.
 

Control of cleaner

Read from the acidity according to “ Analysis Method”.

PC-82OO (2-time dilution) : < 0.10N : change all into fresh solution.
10.O% hydrochloric acid : < 1.O N : change all into fresh solution.

 
Calculation in case of concentration or dilution

ANALYTICAL PROCEDURES

Copper

  1. Pipette 1ml of CZ-8100 bath and add 50ml of deionized water.
  2. Add aqueous ammonia to a dark blue endpoint.
  3. Add 0.2g of 0.4%-Murexide reagent (diluted potassium sulphate).
  4. Titrate with 0.025 M-EDTA from a reddish yellow to a purple endpoint.
  5. 1.5885 x f x V = g/1 Cu
    where, f = the factor of 0.025 M-EDTA (should be = 1)
    V = the titrated volume (ml)

Etch rate

Board : Scrubbed copper clad panel 10 x 10 cm

Process : Measure the board weight to the third decimal point (0.001)*

Treat with CZ-8100
Rinse with water
Dry
Measure the board weight again.
(* use actual equipment in process)

Example : Double-sided board = (initial weight *1 - treated weight *2) 8.9 x 50
 

Acidity of de-smuth

  1. Pipette 1 ml of solution and add 50 ml of deionized water.
  2. Add 2-3 drops of the reagent (Phenolphthalein).
  3. Titrate with 0.O1 N NaOH for cleaner and O.1N NaOH for hydrochloric acid to a reddish purple endpoint.
 

EQUIPMENT MATERIAL
 
MATERIAL
 
 
 MATERIAL
 
 
 SS 3O4
X
Rigid PPE
0
SS 316
X
Soft EPT
X
 Titanium
0
Soft PVC
0
Rigid PVC
0
Soft thermorun
Rigid PP
0
Foamed polymer
0
Rigid PE
0
SS welded
X
 Rigid ulmoler/PE type resin
0
Titanium welded
0
 

0 : Usable, X : Not usable, D : Partly usable

Stainless steel metal parts cannot be used !

* For mark D , contact our Research and Development Division for further information.

  CAUTION IN HANDLING
  1. Provide adequate ventilation in the working area.

  2.  
  3. Do not let the solution leak when it is taken out of the container or into the container.

  4.  
  5. When handling, wear protective coverings such as gloves and goggles to avoid contact with hands, legs, skin and eyes.

  6.  
  7. Wash hands and mouth after handling.

  8.  
  9. Keep the container tightly sealed in a cool and dark place away from direct sunlight.

  10.  
  11. Absorb with sand and remove when leaked.
 

 PHYSICAL PROPERTIES

Test method

Comparison of peel strength between various processes.

Copper surface treatment :
- Chemical : MecEtchBond : CZ-8100
- : MecBrite H2SO4 - H2O2 type
- Mechanical scrubbing
- Black Oxide treatment

Lamination : Prepeg 2 layers

Press condition : Heat at 170°C Pressure 30 kg/cm?
 

Peel strength - Subject to JIS C 6481

Copper foil 70 µm is used
 

 

DELAMINATION CHECK

Compared the deteriorated solder heat resistance based on JIS C 6481.

Delamination 1

Boil at 100°C for 4 hours Heat stress at 260°C
Solder float for 60 seconds

MecEtchBond and Black Oxide treatment caused no blistering, separation or delamination.

Delamination 2.

Pressure-cooker test
121°C, 2atm, 2 hours Heat stress at 260°C
Float on solder for 1 min.
 
Copper concentration 15g/l 30g/l 45g/l
CZ-81OO (old version) 0 D ~ 0 ----
CZ-81OO 0 0 0
 
0 : No delamination.
D : May cause delamination.
X : Cause delamination.
 

CZ-81OO, even under the copper holding capacity 45g/l, keeps high solder heat resistance without causing any delamination

 
MecEtchBond RELIABILITY

1. Electric insulation

 
Initial  Over 1 x 1013 Ohm
After 30 days Over 1 x 1013 Ohm
 
2. Residual ionic contamination  
H2SO4 - H2O2 type  3.5 u gNaC1/sq. inch
MecEtchBond  2.2 u gNaC1/sq. inch
 
 

WASTE TREATMENT

Rely on disposal contractor for disposing of spent solution and water rinse containing much solution.
For disposal of 1st water rinse, perform treatment according to neutralisation coagulation method.

Example of 1st rinse water treatment

 
1st rinse water
 
 
Inorganic coalgulator
Add Ferric Chloride (Possible to use PAC and Aluminium Sulphate)
 
Neutralisation
Add 10-20% slaked lime or caustic soda
 
Anion type high polymer coagulator
 
 
Solid-solution separation
 
 
Supernatant solution discharging
 
 
 
 
Before treatment
After treatment
Copper concentration
(ppm)
4000
1 >

 


Warranty

The information contained herein is believed to be correct, but each user is advised to ensure that the product is suitable for his own purposes before he uses it.The purchaser is solely responsible for any loss, either directly or indirectly arising from the use of this product, or information contained herein.

 

 